Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1353947.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,772.00
Current Penalty: $1,386.00
Issuance Date: 01/04/2019
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 01/10/2019
Gravity: 5
Report ID: 0112600
Contest Date:
Final Order: 02/04/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/04/2019 | $1,386.00 | 01/10/2019 | Serious | |
| Penalty | Z: Issued | 01/04/2019 | $2,772.00 | 01/10/2019 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: a) 203 Walker St., Lenox, MA: On or about October 17, 2018, an employee was observed using a portable extension ladder to access his roof top work location that did not extend the required 3 feet past the upper landing surface.