Violation Detail
Standard Cited: 19100219 B01 Mechanical power-transmission apparatus.
Inspection Nr: 1341398.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,467.00
Current Penalty: $3,913.00
Issuance Date: 11/15/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 11/21/2018
Gravity: 5
Report ID: 0521700
Contest Date:
Final Order: 12/13/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/13/2018 | $3,913.00 | 11/21/2018 | Serious | |
Penalty | Z: Issued | 11/15/2018 | $6,467.00 | 11/21/2018 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(b)(1): Flywheel with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv)(a). a. On or about September 13, 2018, employees were operating The Lewis Wire Straightener Machine and the flywheel not guarded completely, thereby exposing employees to amputation hazards.