Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1291715.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $7,760.40
Issuance Date: 02/23/2018
Nr Instances: 6
Nr Exposed: 5
Abatement Date: 04/11/2018
Gravity: 10
Report ID: 0729700
Contest Date:
Final Order: 03/15/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/15/2018 | $7,760.40 | 04/11/2018 | Serious | |
Penalty | Z: Issued | 02/23/2018 | $12,934.00 | 03/21/2018 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Employees engaged in machining activities at the following pieces of equipment throughout the facility were exposed to struck-by and amputation hazards in that machine guarding was not provided and utilized: a) Fadal machining area in the Main building, the electrical interlock on the door of the Fadal VMC 3016 CNC machine #696, Model #CNC88HS had been bypassed. b) Bertsche, Okuma, and Mori Seiki machining areas in the Main building, the electrical interlocks on the doors of the Bertsche, Okuma, and Mori Seiki CNC machines had been bypassed. c) Makino and Okuma machining areas in the South building, the electrical interlocks on the doors of the Makino and Okuma CNC machines had been bypassed. d) Toyoda machining area in the East building, the electrical interlocks on the doors of the Toyoda CNC machines had been bypassed. e) Both of the Bridgeport Mills in the Small Part area of the Main building, employees were not provided protection from flying chips and debris, the rotating drill chucks were not guarded. f) Both of the Do-All Band Saws in the Small Part area of the Main building, the unused portions of the blades on the two Band-saws were not guarded. 29 CFR 1903.19(d)(1) requires certification and documentation that the abatement of the above violation is completed.