Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1288984.015
Citation: 01005
Citation Type: Serious
Abatement Date: 07/27/2018 2
Initial Penalty: $4,989.00
Current Penalty: $4,989.00
Issuance Date: 07/02/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 1
Report ID: 0419700
Contest Date: 07/24/2018
Final Order: 05/17/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/17/2019 | $4,989.00 | 07/27/2018 | Serious | |
Penalty | C: Contested | 07/30/2018 | $4,989.00 | 07/27/2018 | Serious | |
Penalty | Z: Issued | 07/02/2018 | $4,989.00 | 07/27/2018 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a. On or about January 25, 2018, in the west side of the machine shop, the Racine reciprocating saw had the lower portion of the belt uncovered exposing employees to a caught-in hazard.