Violation Detail
Standard Cited: 19100243 B02 Guarding of portable powered tools.
Inspection Nr: 1283050.015
Citation: 01005
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $4,268.00
Current Penalty: $2,134.00
Issuance Date: 03/02/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/06/2018
Gravity:
Report ID: 0728900
Contest Date:
Final Order: 03/22/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/22/2018 | $2,134.00 | 04/06/2018 | Other | |
Penalty | Z: Issued | 03/02/2018 | $4,268.00 | 04/06/2018 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.243(b)(2): Air hose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected. The employer is exposing employees to struck by hazards when operating pneumatic air equipment. This was most recently documented at 900 Kelly Ryan Dr, Blair, Nebraska on or about December 13, 2017 when a compressed air hose was observed with a hose clamp holding a quick disconnect connector in place.