Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1211861.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,054.00
Current Penalty: $4,375.00
Issuance Date: 08/16/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 09/29/2017
Gravity: 5
Report ID: 0214200
Contest Date: 09/08/2017
Final Order: 03/08/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/08/2018 | $4,375.00 | 09/29/2017 | Serious | |
Penalty | C: Contested | 10/13/2017 | $9,054.00 | 09/29/2017 | Serious | |
Penalty | Z: Issued | 08/16/2017 | $9,054.00 | 09/29/2017 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) Facility Employees who performed maintenance to include applying locks to equipment such as, but not limited to, extruders and dust collectors were not trained on energy control procedures. Violation occurred on or about 02/21/2017.