Violation Detail
Standard Cited: 19260452 B02 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1198878.015
Citation: 01005
Citation Type: Serious
Abatement Date: 06/08/2017 2
Initial Penalty: $12,675.00
Current Penalty: $8,139.00
Issuance Date: 05/26/2017
Nr Instances: 1
Nr Exposed: 300
Related Event Code (REC):
Gravity: 10
Report ID: 0936300
Contest Date: 06/22/2017
Final Order: 10/06/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/06/2017 | $8,139.00 | 06/08/2017 | Serious | |
Penalty | C: Contested | 07/11/2017 | $12,675.00 | 06/08/2017 | Serious | |
Penalty | Z: Issued | 05/26/2017 | $12,675.00 | 06/08/2017 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1926.452(b)(2): Transverse bracing forming an "X" across the width of the scaffold was not installed at the scaffold ends and at least at every third set of posts horizontally (measured from only one end) and every fourth runner vertically. Bracing did not extend diagonally from the inner or outer posts or runners upward to the next outer or inner posts or runners: On December 16, 2016, on the center north face of the construction project, workers were working from tube and coupler scaffolding where the transverse bracing across the width of the scaffold was not installed. Employees were exposed to fall hazards.