Violation Detail
Standard Cited: 19100423 D01 Post-dive procedures.
Inspection Nr: 1198722.015
Citation: 01005
Citation Type: Serious
Abatement Date: 07/06/2017 4
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/16/2017
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0111400
Contest Date:
Final Order: 06/16/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 05/16/2017 | $0.00 | 07/06/2017 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.423(d)(1): The following information was not recorded and maintained for each diving operation: Recorded information shall include(i) Names of dive team members (ii) Date, time, location(iii) diving modes used (iv) General nature of work performed (v) Appropriate underwater and surface conditions(vi) maximum depth and bottom time for each diver: Braintree Water Tank: A dive log was not maintained for operations that occurred on 12-14-16 and 12-15-16 during a dive that involved cleaning and inspecting of a water tank with a water level of approximately 57 feet.