Violation Detail
Standard Cited: 19100219 C04 II Mechanical power-transmission apparatus.
Inspection Nr: 1126202.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $5,000.00
Issuance Date: 07/28/2016
Nr Instances: 3
Nr Exposed: 50
Abatement Date: 08/12/2016
Gravity: 5
Report ID: 0625500
Contest Date: 08/18/2016
Final Order: 06/02/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/02/2017 | $5,000.00 | 08/12/2016 | Serious | |
Penalty | C: Contested | 08/19/2016 | $5,000.00 | 08/12/2016 | Serious | |
Penalty | Z: Issued | 07/28/2016 | $5,000.00 | 08/12/2016 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: (a) Freeze tunnel, control station side: On or about February 11, 2016, employees were exposed to a caught by hazard, while walking by the freeze tunnel that had an exposed rotating shaft with a keyway. (b) Fry line, raw side flour tumbler applicator station: On or about February 12, 2016, employees were exposed to a caught by hazard, while walking and working on the flour tumbler station that had an exposed rotating shaft with a keyway. (c) Fry line, raw side, east: On or about February 17, 2016, employees were exposed to a caught by hazard, while walking by the fry control station that had an exposed rotating shaft with a keyway.