Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
This violation item has been deleted.
Inspection Nr: 1123560.015
Citation: 01005
Citation Type: Serious
Abatement Status:
Initial Penalty: $5,000.00
Current Penalty: $0.00
Issuance Date: 07/29/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/17/2016
Gravity: 5
Report ID: 0316700
Contest Date:
Final Order: 08/19/2016
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/19/2016 | $0.00 | 08/17/2016 | Serious | |
| Penalty | Z: Issued | 07/29/2016 | $5,000.00 | 08/17/2016 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Ductile Muller - On February 8, 2016 and times prior the employer failed to adequately guard the Muller south side hatch door. The metal hatch door would be hinged open while employees observed the internal components while they were in motion. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.