Violation Detail
Standard Cited: 19100027 B03 Scaffolds and rope descent systems.
Inspection Nr: 1107787.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $1,600.00
Current Penalty: $960.00
Issuance Date: 05/13/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/09/2016
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 06/07/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/07/2016 | $960.00 | 06/09/2016 | Serious | |
Penalty | Z: Issued | 05/13/2016 | $1,600.00 | 06/09/2016 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.27(b)(3): Fastenings were not an integral part of the fixed ladder design: A.) Falls Creek Powdered Metals, Inc., 82 Industrial Drive, Brockway, PA, 15824, production area, on or about November 23, 2015 and times prior thereto: Employees climb up and down a fixed ladder below grade at the Gasbarre 60T powered metal press (M9) to perform maintenance activities including, but not limited to, removing and replacing core rods for a second Gasbarre 60T powered metal press (M5). The fixed ladder was not bolted to the wall of the pit.