Violation Detail
Standard Cited: 19100147 C07 I A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1085441.015
Citation: 01005
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 02/09/2016
Nr Instances: 2
Nr Exposed: 5
Abatement Date: 03/28/2016
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 03/03/2016
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 02/09/2016 | $7,000.00 | 03/28/2016 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: (a) The employer did not ensure that authorized employees had received training in the methods and means necessary for energy isolation for equipment such as, but not limited to, the Milnor dryer and Pellerin Milnor conveyor. On or about August 13, 2015, an employee was propelled into an industrial dryer when the conveyor system activated. The dryer subsequently activated with the employee trapped inside. (b) The employer did not ensure that authorized employees had received training in the methods and means necessary for energy isolation for equipment such as, but not limited to, the Milnor dryer and Pellerin Milnor conveyor. On or about August 11, 2015, an employee was conducting maintenance work without using proper hazardous energy control procedures.