Violation Detail
Standard Cited: 19100242 B Hand and portable powered tools and equipment, general.
Inspection Nr: 1010176.015
Citation: 01005
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $1,600.00
Current Penalty: $800.00
Issuance Date: 01/21/2015
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 06/05/2015
Gravity: 5
Report ID: 0336000
Contest Date: 02/27/2015
Final Order: 04/23/2015
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 04/23/2015 | $800.00 | 06/05/2015 | Serious | |
| Penalty | C: Contested | 03/23/2015 | $1,600.00 | Serious | ||
| Penalty | Z: Issued | 01/21/2015 | $1,600.00 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a.) Rohr Industries, Inc. 201 Stackpole Street, St. Marys, PA, Production Area-Lathe 11, on or about November 21st, 2014, and times prior thereto: Employees were utilizing compressed air to clean/dry off various metal parts that were saturated with water/debris. Measurements of compressed air next to Lathe 11 were above 60 p.s.i. b.) Rohr Industries, Inc. 201 Stackpole Street, St. Marys, PA, Production Area-Lathe 12, on or about November 21st, 2014, and times prior thereto: Employees were utilizing compressed air to clean/dry off various metal parts and the chuck within the CNC machine (Lathe 12) that were saturated with water/debris. Measurements of compressed air next to Lathe 12 were above 60 p.s.i.