Violation Detail
Standard Cited: 19260852 F Chutes.
Inspection Nr: 1162895.015
Citation: 01004I
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $8,873.00
Current Penalty: $0.00
Issuance Date: 01/18/2017
Nr Instances: 1
Nr Exposed: 16
Abatement Date: 07/10/2018
Gravity: 10
Report ID: 0213100
Contest Date: 02/07/2017
Final Order: 07/23/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 07/23/2018 | $0.00 | 07/10/2018 | Serious | |
Penalty | C: Contested | 02/08/2017 | $8,873.00 | 01/26/2017 | Serious | |
Penalty | Z: Issued | 01/18/2017 | $8,873.00 | 01/26/2017 | Serious |
Text For Citation: 01 Item/Group: 004I Hazard:
29 CFR 1926.852(f): Where the material is dumped from mechanical equipment or wheelbarrows, a securely attached toeboard or bumper, not less than 4 inches thick and 6 inches high, were not provided at each chute opening: a) On and before 7/19/2016, 960 Broadway building north side, employees removing hardwood floors and other demolition debris were required to throw and dump material down the elevator shaft. The employer did not install a toeboard or bumper.