Violation Detail
Standard Cited: 19260651 H01 Specific Excavation Requirements.
This violation item has been deleted.
Inspection Nr: 1812284.015
Citation: 01004E
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/09/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0521700
Contest Date:
Final Order: 08/04/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/04/2025 | $0.00 | Serious | ||
Penalty | Z: Issued | 07/09/2025 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 004E Hazard:
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation. a) On or about March 20, 2025, at the above addressed jobsite, employees installing storm sewer line were working in an excavation with a maximum approximate depth of six (6) feet eight (8) inches where there was accumulated and accumulating water, thereby exposing employees to cave-in hazards associated with water accumulation.