Violation Detail
Standard Cited: 19100134 H04 Respiratory Protection.
Inspection Nr: 1726056.015
Citation: 01004E
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/10/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 07/02/2024
Gravity: 5
Report ID: 0830400
Contest Date:
Final Order: 07/01/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/01/2024 | $0.00 | 07/02/2024 | Other | |
Penalty | Z: Issued | 06/10/2024 | $0.00 | 07/02/2024 | Serious |
Text For Citation: 01 Item/Group: 004E Hazard:
29 CFR 1910.134(h)(4): Respirators that failed an inspection or were otherwise found to be defective were not removed from service and discarded or repaired: (a)Wheeler Tank Manufacturing, Inc. at 4001 North 4th Avenue, Sioux Falls, SD 57104: On or about and at times prior to February 27, 2024, the employer did not ensure that employees removed the NOVA abrasive blasting hood from service when the collar was found to be defective and not providing an appropriate seal. This condition exposed employees to chemical hazards.