Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 1585438.015
Citation: 01004E
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/06/2022
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 09/30/2022
Gravity: 10
Report ID: 0830400
Contest Date:
Final Order: 10/03/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/03/2022 | $0.00 | 09/30/2022 | Serious | |
Penalty | Z: Issued | 09/06/2022 | $0.00 | 09/30/2022 | Serious |
Text For Citation: 01 Item/Group: 004E Hazard:
29 CFR 1910.219(f)(3):Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: (a) Fermentationexperts, Inc. at 1201 North Ellis Road, Sioux Falls, SD 57107: On or about and at times prior to March 24, 2022, the employer did not ensure the chain and sprocket on the auger systems within the chiller room was guarded. This condition exposed employee to caught-in and amputation hazards associated with the unguarded drive chain and sprocket.