Violation Detail
Standard Cited: 19100107 I03 Spray finishing using flammable and combustible materials.
Inspection Nr: 898505.015
Citation: 01004D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/06/2013
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 01/15/2014
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 09/13/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/13/2013 | $0.00 | 01/15/2014 | Serious | |
| Penalty | Z: Issued | 09/06/2013 | $0.00 | 10/24/2013 | Serious |
Text For Citation: 01 Item/Group: 004D Hazard:
29 CFR 1910.107(i)(3): Equipment approval and specifications. Electrostatic hand spray apparatus and devices used in connection with coating operations shall be of approved types. The high voltage circuits shall be designed so as to not produce a spark of sufficient intensity to ignite any vapor-air mixtures nor result in appreciable shock hazard upon coming in contact with a grounded object under all normal operating conditions. The electrostatically charged exposed elements of the handgun shall be capable of being energized only by a switch which also controls the coating material supply. a. On or about April 1, 2013, in the touch up powder coating area(s), ordinary (non-approved) wiring and associated electrostatic hand spraying equipment was located inside the spray area(s). Employees were exposed to electrical hazards when the non approved wiring and electrostatic hand spraying equipment was used in an area where combustible dust was transferred and could result in a spark being generated in a combustible atmosphere resulting in a fire/explosion hazard.
Translate