Violation Detail
Standard Cited: 19100147 F03 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1719998.015
Citation: 01004D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $0.00
Issuance Date: 06/05/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/02/2024
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 06/20/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/20/2024 | $0.00 | 07/02/2024 | Serious | |
Penalty | Z: Issued | 06/05/2024 | $16,131.00 | 07/02/2024 | Serious |
Text For Citation: 01 Item/Group: 004D Hazard:
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew: On or about December 31, 2023, at the Mainline No. 2 Core Station, PA-134, employees performed servicing and maintenance activities such as, but not limited to adjusting the chain on the top of the sprocket of the hoist table, without group energy control procedures being utilized to ensure protection of all employees.