Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1298174.015
Citation: 01004D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/22/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 07/19/2018
Gravity: 5
Report ID: 0316700
Contest Date:
Final Order: 07/11/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/11/2018 | $0.00 | 07/19/2018 | Serious | |
| Penalty | Z: Issued | 06/22/2018 | $0.00 | 07/19/2018 | Serious |
Text For Citation: 01 Item/Group: 004D Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting face piece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) SPRAY ROOM AREA - Employee(s) spray painted lumber processing equipment where the employer required the employee(s) to wear 3M half mask respirators, and the employer did not provide any kind of fit test to the painter(s), on or about February 28, 2018. No abatement certification or documentation required.