Violation Detail
Standard Cited: 19100146 K03 I Permit-required confined spaces
Inspection Nr: 1248490.015
Citation: 01004D
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,675.00
Current Penalty: $0.00
Issuance Date: 09/14/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0317500
Contest Date:
Final Order: 10/06/2017
Related Event Code (REC): R
Emphasis:
Substance: 1900
Substance: X100
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/06/2017 | $0.00 | Serious | ||
| Penalty | Z: Issued | 09/14/2017 | $12,675.00 | Serious |
Text For Citation: 01 Item/Group: 004D Hazard:
29 CFR 1910.146(k)(3)(i): Each authorized entrant did not use a chest or full body harness, with a retrieval line attached at the center of the entrant's back near shoulder level, or above the entrant's head: a) In the North Shop, on or about July 20, 2017 - A welder entering high pressure tank car TILX 303142 failed to use a harness with a retrieval line attached. The welder lost consciousness in the oxygen depleted atmosphere and needed to be rescued. Two employees lost consciousness inside the tank car attempting to rescue the welder.