Violation Detail
Standard Cited: 19100107 H02 Spray finishing using flammable and combustible materials.
Inspection Nr: 898505.015
Citation: 01004C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/06/2013
Nr Instances: 2
Nr Exposed: 5
Abatement Date: 01/15/2014
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 09/13/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/13/2013 | $0.00 | 01/15/2014 | Serious | |
| Penalty | Z: Issued | 09/06/2013 | $0.00 | 11/15/2013 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1910.107(h)(2): Type approval. Electrostatic apparatus and devices used in connection with coating operations shall be of approved types. a. On or about April 1, 2013, in the two (2) touch up powder coating spray area(s), electrostatic apparatus equipment and devices were used to spray combustible powder. The combustible powder spray application equipment and related ventilation system was not approved and listed by a nationally recognized testing laboratory exposing employees to hazards associated with combustible dust.
Translate