Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1757677.015
Citation: 01004C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/06/2024
Nr Instances: 1
Nr Exposed: 9
Abatement Date: 01/27/2025
Gravity: 10
Report ID: 0627700
Contest Date:
Final Order: 01/14/2025
Related Event Code (REC):
Emphasis:
Substance: 9000
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/14/2025 | $0.00 | 01/27/2025 | Serious | |
Penalty | Z: Issued | 12/06/2024 | $0.00 | 12/30/2024 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): On or about June 13, 2024, at the 4th floor of the courthouse, employees were required to wear N95 half mask tight-fitting respirators and were not provided respirator fit testing. Employees used jackhammers and a circular saw to remove building materials that contained crystalline silica.