Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1591347.015
Citation: 01004C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,164.00
Current Penalty: $0.00
Issuance Date: 09/16/2022
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 10/20/2022
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 10/12/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/12/2022 | $0.00 | 10/20/2022 | Serious | |
| Penalty | Z: Issued | 09/16/2022 | $6,164.00 | 10/20/2022 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) On or about April 22, 2022, at the Waterbury Farrel Cold Heading machine model no. 0, machine #49, aisle 3, row 9, the flywheel pulley located approximately three feet from the floor was not properly guarded. This exposed employees to a struck by and caught in hazard.