Violation Detail
Standard Cited: 19100147 C04 II C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1563757.015
Citation: 01004C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/05/2022
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 09/06/2022
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 06/01/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/01/2022 | $0.00 | 09/06/2022 | Serious | |
Penalty | Z: Issued | 05/05/2022 | $0.00 | 06/01/2022 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. a) At 830 Georgia 42 South, McDonough, GA 30252, on or about November 9, 2021, employees performing service and/or maintenance on the Laaderberg Tunnel equipment used to manufacture foam mattresses were exposed to an amputation and a caught-in hazards, in that procedures developed did not clearly and specifically outline the steps for placement, removal and transfer of lockout and tagout devices for pneumatic pressure, thermal and mechanical energy sources. a. The Laaderberg tunnel equipment with electrical 440V, pneumatic approximately 80 psi, and thermal above 37.6C (99F) at the trough during initial liquid stage