Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1528071.015
Citation: 01004C
Citation Type: Serious
Abatement Date: 11/23/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/27/2021
Nr Instances: 2
Nr Exposed: 5
Related Event Code (REC):
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 11/24/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/24/2021 | $0.00 | 11/23/2021 | Serious | |
Penalty | Z: Issued | 10/27/2021 | $0.00 | 11/23/2021 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o)(a): On or about April 28, 2021, the employer did not install guards on the following vertical belts that exposed employees to caught-in hazards: a. The belts on top of the CME pellet machine. b. The vertical belt on the west side of the red Van Dale mixer.