Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1450674.015
Citation: 01004C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/19/2020
Nr Instances: 1
Nr Exposed: 25
Abatement Date: 07/22/2020
Gravity: 1
Report ID: 0420600
Contest Date:
Final Order: 06/15/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/15/2020 | $0.00 | 07/22/2020 | Serious | |
Penalty | Z: Issued | 05/19/2020 | $0.00 | 06/22/2020 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a. On or about 12/12/2019, at the fabrication area shear line 2, employees were exposed to a caught-in and struck by hazards, in that, a vertical belt at the side of the shear line below the point of operation guard did not have a guard to fully enclose the moving parts.