Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1298176.015
Citation: 01004C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/11/2018
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 05/29/2018
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 05/09/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/09/2018 | $0.00 | 05/29/2018 | Serious | |
Penalty | Z: Issued | 04/11/2018 | $0.00 | 05/29/2018 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: At the machine #7-002 work center, where the robot interlock gate was used by the operator standing in the robot area to work on the die cast machine, the lockout written procedure did not state how de-energization was to be made. Abatement documentation is required for this violation.