Violation Detail
Standard Cited: 19101027 M04 I Cadmium
Inspection Nr: 1243236.015
Citation: 01004C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/15/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/12/2018
Gravity: 5
Report ID: 0524200
Contest Date:
Final Order: 01/17/2018
Related Event Code (REC):
Emphasis:
Substance: C141
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/17/2018 | $0.00 | 01/12/2018 | Serious | |
Penalty | Z: Issued | 12/15/2017 | $0.00 | 01/12/2018 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1910.1027(m)(4)(i): The employer did not institute a training program for all employees who were potentially exposed to cadmium, ensure employee participation in the program, and maintain a record of the contents of such program. a) On June 28, 2017, eWorks Electronic Services, Inc. did not institute a training program, with employee participation, for workers who were potentially exposed to cadmium when dismantling Cathode Ray Tube monitors and/or dry-sweeping in the Cathode Ray Tube Line and the Baler Areas.