Violation Detail
Standard Cited: 19100430 C03 II Equipment.
Inspection Nr: 1007743.015
Citation: 01004C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/08/2015
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 01/30/2017
Gravity: 10
Report ID: 0522500
Contest Date: 04/17/2015
Final Order: 12/30/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 12/30/2016 | $0.00 | 01/30/2017 | Serious | |
Penalty | C: Contested | 04/21/2015 | $0.00 | 04/28/2015 | Serious | |
Penalty | Z: Issued | 04/08/2015 | $0.00 | 04/28/2015 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1910.430(c)(3): Umbilicals shall: 29 CFR 1910.430(c)(3)(ii): Be made of kink-resistant materials; and a. On or about October 11, 2014 through October 14, 2104, located at the Discover Financial Services' north retention pond, employees were conducting surfaced-supplied diving in order to remove pond muck with a suction hose. The employees were supplied air from a 26 gallon Central Pneumatic air compressor, model number 68067, serial number 06047 that had a 1/4 inch i.d. PVC air hose attached that was used in part to supply air to the divers which was not made of kink-resistant materials, thereby exposing the divers to a drowning hazard in 10-12 feet deep water.