Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 903994.015
Citation: 01004B
Citation Type: Other
Abatement Date: 08/27/2013 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/01/2013
Nr Instances: 15
Nr Exposed: 37
Related Event Code (REC):
Gravity:
Report ID: 0419400
Contest Date:
Final Order: 08/27/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/27/2013 | $0.00 | 08/27/2013 | Other | |
Penalty | Z: Issued | 08/01/2013 | $0.00 | 08/27/2013 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection: (a) 820 Highway 7 North in Holly Springs, MS - On or about April 30, 2013, periodic inspections of the energy control procedures were not being certified and maintained on equipment such as but not limited to extruders, air compressors, MTI mixer, dry blend cooler, etc.