Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1787526.015
Citation: 01004B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/30/2025
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 02/19/2025
Gravity: 10
Report ID: 0522500
Contest Date: 02/26/2025
Final Order:
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 04/08/2025 | $0.00 | 02/19/2025 | Serious | |
Penalty | Z: Issued | 01/30/2025 | $0.00 | 02/19/2025 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(c)(6)(i):The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) Located at 150 Fourth Avenue, Mount Sterling, OH 43143: On and about November 13, 2024, the employer did not ensure periodic inspections of energy control procedures of the extruder were conducted annually. b) Located at 150 Fourth Avenue, Mount Sterling, OH 43143: On and about November 13, 2024, the employer did not ensure periodic inspections of energy control procedures of the thermoform machines were conducted annually. c) Located at 150 Fourth Avenue, Mount Sterling, OH 43143: On and about November 13, 2024, the employer did not ensure periodic inspections of energy control procedures of the trim press machines were conducted annually.