Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1748576.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/16/2024
Nr Instances: 4
Nr Exposed: 2
Abatement Date: 01/15/2025
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 11/12/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/12/2024 | $0.00 | 01/15/2025 | Serious | |
| Penalty | Z: Issued | 10/16/2024 | $0.00 | 11/19/2024 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) On or about May 16, 2024, and dates prior, at the polishing station on furnace line #1: Employees working at/or around the energized exposed 1 inch diameter brush drive shaft end(s) during machine adjustment were exposed to a caught-on hazard, in-that the exposed rotating shaft end(s) was not guarded by a non-rotating cap or equivalent sleeve.