Violation Detail
Standard Cited: 19100147 D04 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1723259.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/21/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 04/01/2024
Gravity: 10
Report ID: 0524500
Contest Date:
Final Order: 04/16/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/16/2024 | $0.00 | 04/01/2024 | Serious | |
Penalty | Z: Issued | 03/21/2024 | $0.00 | 04/01/2024 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(d)(4): The established procedure for the application of energy control did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about January 17, 2024, an employee was exposed to amputation hazards, while performing the maintenance and servicing operation of changing blades in a Marvel Horizontal Bandsaw. The employer failed to implement energy control application steps. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards, at the Danville, Illinois facility.