Violation Detail
Standard Cited: 19100134 E01 Respiratory Protection.
Inspection Nr: 1705321.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/12/2024
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/10/2024
Gravity: 5
Report ID: 0830600
Contest Date:
Final Order: 05/02/2024
Related Event Code (REC):
Emphasis:
Substance: 9000
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/02/2024 | $0.00 | 05/10/2024 | Serious | |
| Penalty | Z: Issued | 04/12/2024 | $0.00 | 05/10/2024 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) 5105 DTC Parkway, Greenwood Village, CO 80111: On or about October 23, 2023, and at times prior, employees who had not been medically evaluated for respirator use wore tight fitting half and full-face respirators when grinding joints in a concrete parking deck, applying chemical sealers including, but not limited to, respirable crystalline silica, MasterSeal NP2, and cleaning equipment with SpecChem Xylene.