Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1647457.015
Citation: 01004B
Citation Type: Serious
Abatement Date: 06/05/2023 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/09/2023
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0729700
Contest Date:
Final Order: 06/08/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/08/2023 | $0.00 | 06/05/2023 | Serious | |
Penalty | Z: Issued | 05/09/2023 | $0.00 | 06/05/2023 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): Employees engaged in maintenance/housekeeping activities in the equipment room of the facility were exposed to in-going nip point hazards. The drive belts on the double stack pumping station units were not provided with fully enclosed guards. In-going nip points were created by two exposed belts and associated pulleys on the back of the machine.