Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1560602.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/15/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/12/2022
Gravity: 5
Report ID: 0729700
Contest Date:
Final Order: 01/11/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/11/2022 | $0.00 | 01/12/2022 | Serious | |
Penalty | Z: Issued | 12/15/2021 | $0.00 | 01/12/2022 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.219(e)(1)(i):Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: In the Maintenance Area, employee(s) operating the Bridgeport Drill Press were exposed to amputation hazards in that the belt on top of the machine was not guarded.