Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1524699.015
Citation: 01004B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/28/2021
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 10/25/2021
Gravity: 5
Report ID: 0316700
Contest Date: 01/27/2022
Final Order: 07/30/2023
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 07/30/2023 | $0.00 | 10/25/2021 | Serious | |
Penalty | C: Contested | 02/04/2022 | $0.00 | 10/25/2021 | Serious | |
Penalty | Z: Issued | 09/28/2021 | $0.00 | 10/25/2021 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belts were not enclosed by guards conforming to the requirements specified at 29 CFR 1910.219(m) and (o): (a) Lower Building - The inclined belts (below waist level) on the motor and saw arbor on the saw known as Big Red did not have guarding, exposing employees to caught-in hazards, on or about the week of April 5, 2021. (b) Lower Building - The vertical belt off the motor (at floor level) on the Jackson 8-inch notcher did not have guarding, exposing employees to caught-in hazards, on or about the week of April 5, 2021. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.