Violation Detail
Standard Cited: 19100219 E03 Mechanical power-transmission apparatus.
Inspection Nr: 1371884.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/21/2019
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 07/29/2019
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 07/10/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/10/2019 | $0.00 | 07/29/2019 | Serious | |
Penalty | Z: Issued | 06/21/2019 | $0.00 | 07/29/2019 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.219(e)(3): Vertical and inclined belts were not enclosed by a guard conforming to the standards in paragraphs specified in 29 CFR 1910.219(m) and (o): a) On or about 1/17/2019, the #3 Punch Machine had ingoing nip point exposure for belts and pulleys. b) On or about 1/17/2019, the 33 RD Machine had exposed belt and pulley nip points.