Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1353050.015
Citation: 01004B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/16/2018
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 01/07/2019
Gravity: 5
Report ID: 0729300
Contest Date: 12/06/2018
Final Order: 11/25/2019
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/25/2019 | $0.00 | 01/07/2019 | Serious | |
Penalty | C: Contested | 12/06/2018 | $0.00 | 01/07/2019 | Serious | |
Penalty | Z: Issued | 11/16/2018 | $0.00 | 01/07/2019 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: At 6240 McKissock Avenue, St. Louis, MO, specifically inside of the Bio Washer and Tub Washer Departments, the horizontal shaft powering the conveyor belt was inadequately guarded. The numerous openings in the belt directly in front of the shaft measured approximately 1" X 2" in size. The unguarded end of this conveyor system was approximately three feet above the concrete floor. This violation was noted on 10/16/18.