Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1336566.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/05/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/15/2019
Gravity: 10
Report ID: 0215000
Contest Date: 03/04/2019
Final Order: 03/05/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/05/2020 | $0.00 | 02/15/2019 | Serious | |
Penalty | C: Contested | 03/18/2019 | $0.00 | 02/15/2019 | Serious | |
Penalty | Z: Issued | 02/05/2019 | $0.00 | 02/15/2019 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section Location: 5401 1st Ave, Brooklyn NY On or about: August 07, 2018 a) Employer did not develop or utilize procedures to control potentially hazardous energy while mechanic serviced and maintained melting machines, cutter machines and shredders.