Violation Detail
Standard Cited: 19100147 F03 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1300600.015
Citation: 01004B
Citation Type: Serious
Abatement Date: 10/03/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/16/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 09/10/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/10/2018 | $0.00 | 10/03/2018 | Serious | |
Penalty | Z: Issued | 08/16/2018 | $0.00 | 10/03/2018 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: On or about June 15, 2018, the employer failed to ensure that each authorized employee working on equipment affixed a personal lockout device. Mixing Unit Lead Operators will clean the rotating shafts and blades of the four (4) Myers Mixers at least weekly. Management will, at times, affix a lockout device to control potentially hazardous electric energy, however, not all authorized employees affix personal lockout devices. The mixing blades are powered by electric energy and have a pneumatic ram that lifts/lowers them into the mixing tank.