Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1292048.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,055.00
Current Penalty: $0.00
Issuance Date: 05/07/2018
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/17/2018
Gravity: 10
Report ID: 0215000
Contest Date:
Final Order: 06/05/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/05/2018 | $0.00 | 05/17/2018 | Serious | |
Penalty | Z: Issued | 05/07/2018 | $9,055.00 | 05/17/2018 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: Site: 21 Belvidere Street Brooklyn, NY On or about 2/1/18 a) Employees engaged in metal bending operations were not protected while using a Chicago, model 131 press brake.