Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1292018.015
Citation: 01004B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/25/2018
Nr Instances: 2
Nr Exposed: 5
Abatement Date: 08/22/2018
Gravity:
Report ID: 0523900
Contest Date: 08/20/2018
Final Order: 09/06/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/06/2019 | $0.00 | 08/22/2018 | Other | |
Penalty | C: Contested | 08/22/2018 | $0.00 | 08/22/2018 | Serious | |
Penalty | Z: Issued | 07/25/2018 | $0.00 | 08/22/2018 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Laminate countertop plant, Lines 1 and 2; Electrical and pneumatic sources of energy were not isolated during cleaning activities on the line 1 and 2 quad saw machines.