Violation Detail
Standard Cited: 19100107 E09 Spray finishing using flammable and combustible materials.
Inspection Nr: 1281130.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/11/2018
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 04/23/2018
Gravity: 1
Report ID: 0626700
Contest Date:
Final Order: 05/01/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/01/2018 | $0.00 | 04/23/2018 | Serious | |
| Penalty | Z: Issued | 04/11/2018 | $0.00 | 04/23/2018 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.107(e)(9): Flammable liquids for use in spraying operations were transferred from one container to another without both containers being effectively bonded and grounded to prevent discharge sparks of static electricity: a) Inside the paint mixing room, where the 55-gallon drum that contained MEK was not grounded and bonded.