Violation Detail
Standard Cited: 19100219 C04 II Mechanical power-transmission apparatus.
Inspection Nr: 1279976.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/04/2018
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 05/07/2018
Gravity: 5
Report ID: 0213600
Contest Date:
Final Order: 04/24/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/24/2018 | $0.00 | 05/07/2018 | Serious | |
| Penalty | Z: Issued | 04/04/2018 | $0.00 | 05/07/2018 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: a) On or about 11/30/17 on the outside roll grader system; employees who work in and around the roll topper and sizing chain were exposed to caught in hazard when there was an open keyway on the rotating drive shaft of the roll toper, located at waist height on the north side of the work platform. ABATEMENT CERTIFICATION REQUIRED