Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1263114.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/02/2018
Nr Instances: 1
Nr Exposed: 13
Abatement Date:
Gravity: 1
Report ID: 0134000
Contest Date:
Final Order: 03/23/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/23/2018 | $0.00 | Serious | ||
Penalty | Z: Issued | 03/02/2018 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): Location: Facility On or about September 12, 2017, the employer did not fit test employees that wore half face respirators and filtering face piece respirators while debarring, sanding, polishing various metal parts, and running CNC machines while cutting with coolant.