Violation Detail
Standard Cited: 19100147 F03 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1260126.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,163.00
Current Penalty: $0.00
Issuance Date: 02/02/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/14/2018
Gravity: 5
Report ID: 0521700
Contest Date:
Final Order: 02/12/2018
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/12/2018 | $0.00 | 02/14/2018 | Serious | |
Penalty | Z: Issued | 02/02/2018 | $10,163.00 | 02/14/2018 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: Water house area - On or about August 28, 2017, supervisor(s), lead(s) and maintenance were required to work together to remove a jam (25 trays or more) inside the machine. Each authorized employee (a supervisor and a lead) did not affix a personal lockout or tagout device to the group lockout device (the new key system) before working on the machine or equipment. Employees were thereby exposed to the hazards of inadvertent start-up of the equipment.