Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1256264.015
Citation: 01004B
Citation Type: Serious
Abatement Date: 08/16/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/05/2018
Nr Instances: 1
Nr Exposed: 8
Related Event Code (REC):
Gravity: 10
Report ID: 0418300
Contest Date: 03/06/2018
Final Order: 08/16/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 08/16/2019 | $0.00 | 08/16/2019 | Serious | |
Penalty | C: Contested | 03/08/2018 | $0.00 | 02/12/2018 | Serious | |
Penalty | Z: Issued | 02/05/2018 | $0.00 | 02/12/2018 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) On or about 8/16/2017 - Extrusion Department, the lines were not turned off or shut down to stop the rotating godet rollers when employees removed wraps from the rollers exposing employees to the caught-in hazards of the in-running nip points between the web and the rollers and between two rollers.