Violation Detail
Standard Cited: 19260502 D16 IV Fall protection systems criteria and practices.
Inspection Nr: 1249360.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/25/2017
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 10/02/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 08/25/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1926.502(d)(16)(iv): Personal fall arrest systems, when stopping a fall, did not bring an employee to a complete stop and/or and did not limit maximum deceleration distance to 3.5 feet (1.07 m): a) South side of roof, east end, on or about 7-20-17: Four employees were working at the edge of a barrel roof, with a personal fall arrest system that was rigged such that the deceleration distance was greater than 3.5 feet, exposing the employees to a fall hazard of 26 feet 3 inches to the ground below. b) South side of roof, east end, on or about 7-20-17: Four employees were working at the edge of a barrel roof, with a personal fall arrest system that was rigged such that the deceleration distance was greater than 3.5 feet, exposing the employees to a fall hazard of 10 feet 8 inches to a roof below.